Q.I changed the value of "Initial coordinate generation and wrap setting range" in Motor and Mechanism (Coordinate/JOG/Return-to-Home) setting under Parameter using the support software MEXE02 on AZ Series, but after the power supply was turned on again, an
The value that can be set in the "Initial Coordinate Generation and Wrap Setting Range" must be an integer when applied to the following two formulas. If you input a value that does not meet this condition, an alarm of wrap setting error will be generated.
Condition 1
- ∗1
- Motor Frame Size 20 mm and 28 mm: 900
- ∗2
- Setting Value:
0.5~1,800.0 (motor frame size 20 mm and 28 mm: 0.5~900.0)
Setting range is to the 1st decimal place
From Condition 1, the only values that can be set are the numbers in the table below.

- *The values enclosed in bold borders cannot be set for motors with frame size of 20 mm or 28 mm.
Condition 2
Technical Support Tools
Easily determine whether you can use the wrap function or not simply by entering your requirements online.
At the same time as determining yes/no, the setting values for the "Gear ratio" and "wrap setting range" are automatically calculated.
Determines Whether or Not the Wrap Function Can Be Used (Applicable Products: AZ Series)
Product Category: αSTEP, Electric Actuators
Model and Series: AZ Series, Electric Actuators AZ Series Equipped
Description: Usage and Setting Methods, Abnormalities and Troubles
FAQ No.: 311
E-Mail an Technischen Support
Nach dem Öffnen der E-Mail werden wir den Inhalt prüfen und uns mit Ihnen in Verbindung setzen. Bitte beachten Sie, dass wir Sie je nach Art Ihrer Anfrage u. U. telefonisch kontaktieren.