αSTEP Battery-Free Built-In Absolute Encoder AZ Series
AZD-AEP

Control Circuit
Produktklassifikation | Produktname | Preis | Versand |
---|---|---|---|
Control Circuit | AZD-AEP | 618.00 € | Up to 20 pcs Estimated Ship 4weeks |
Inklusive
- Control Circuit: Main Power Supply/Regeneration Resistor Connector (CN4), Connector for 24 VDC Power Supply input·Electromagnetic Brake Connector·Regeneration Unit Thermal Input·power removal signal input (CN1), I/O Signal Connector (CN7), Connector Wiring Lever
Spezifikationen
Abmessungen

Control Circuit
Daten-Download
Weitere Spezifikationen
Communication Specifications
Communication Protocol | EtherNet/IP (CT16 compliant) | |
---|---|---|
Vendor ID | 187: Oriental Motor Company | |
Device Type | 43: Generic Device | |
Transmission Rate | 10/100 Mbps (autonegotiation) | |
Mode | Full duplex/half duplex (autonegotiation) | |
Cable Specification | Shielded twisted pair (STP) cable Straight/cross, category 5e or higher |
|
Number of Occupied Bytes | Output (Scanner → Driver) | 40 bytes |
Input (Driver → Scanner) | 56 bytes | |
Implicit Communication | Number of Connections Supported | 2 |
Connection Type | Exclusive owner, input only | |
Communication Cycle (RPI) | 1~3200 ms | |
Connection Type (Scanner → Driver) | Point−to−Point | |
Connection Type (Driver → Scanner) | Point−to−point, multicast | |
Data Trigger | Cyclic | |
IP Address Setting Method | IP address setting switches, parameters, DHCP | |
Supported Topologies | Star, linear, ring (device level ring) |
Driver Specifications
Driver Product Name | AZD-AD, AZD-CD | AZD-AM3, AZD-CM3 AZD-AS3, AZD-CS3 |
AZD-AEP, AZD-CEP AZD-AED, AZD-CED AZD-APN, AZD-CPN AZD-AX, AZD-CX AZD-A, AZD-C |
|
---|---|---|---|---|
Interface |
Pulse Input | - | - |
|
Control Input | 10 Points Photocoupler |
4 Points Photocoupler |
6 Points Photocoupler |
|
Pulse output | 2 Points Line Driver |
- | 2 Points Line Driver |
|
Control output | 6 Points Photocoupler and Open-Collector |
3 Points Photocoupler and Open-Collector |
6 Points Photocoupler and Open-Collector |
|
Power Shut Down Input Signals |
2 Points Photocoupler |
|||
Power Shut Down Monitor Output |
1 Point Photocoupler and Open-Collector |
Driver function
Built-In Controller Type | Pulse Input Type with RS-485 Communication | Pulse Input Type |
EtherNet/IP Compatible PROFINET Compatible |
||||
---|---|---|---|---|---|---|---|
Number of Positioning Data Sets | 256 Points | 256 Points*1 | 256 Points | ||||
Remote I/O | Input | 16 Points | - | 16 Points | |||
Output | 16 Points | - | 16 Points | ||||
Setting Tool | Support Software MEXE02 | ||||||
Coordinates Management Method | Battery-free Absolute System | ||||||
Operation | Positioning Operation | Product Line | Positioning Operation | ○ | ○ | ○*1 | ○ |
Positioning Push-Motion Operation*2 |
○ | ○ | ○*1 | ○ | |||
Fastening method | Single-motion Operation | ○ | ○ | ○*1 | ○ | ||
Sequential Operation | ○ | ○ | ○*1 | ○ | |||
Multistep Speed-Change (Configuration connection) |
○ | ○ | ○*1 | ○ | |||
Sequence control | Loop Operation (Repeating) |
○ | ○ | ○*1 | ○ | ||
Event Jump Operation | ○ | ○ | ○*1 | ○ | |||
Speed Control Operation (Continuous operation) | ○ | ○ | ○*1 | ○ | |||
Return-To-Home Operation | Return-To-Home Operation | ○ | ○ | ○ | ○ | ||
High-speed return-to-home operation | ○ | ○ | ○ | ○ | |||
JOG Operation | ○ | ○ | ○ | ○ | |||
Monitor/Information | Waveform Monitoring | ○ | ○ | ○ | ○ | ||
Overload Detection | ○ | ○ | ○ | ○ | |||
Overheat Detection (Motor and Driver) |
○ | ○ | ○ | ○ | |||
Position/Speed Information | ○ | ○ | ○ | ○ | |||
Temperature Detection (Motor and Driver) |
○ | ○ | ○ | ○ | |||
Motor Load Factor | ○ | ○ | ○ | ○ | |||
Travel Distance , Cumulative Travel Distance | ○ | ○ | ○ | ○ | |||
Alarm | ○ | ○ | ○ | ○ |
- *1
- It can be used by setting it with the MEXE02 support software.
- *2
- Push-motion operation is not available for the geared motor and electric actuator DGII Series.
General Specifications
Motor | Driver | |||
---|---|---|---|---|
Built-in Controller Type Pulse Input Type with RS-485 Communication EtherNet/IP Compatible EtherCAT Compatible PROFINET Compatible |
Pulse Input Type MECHATROLINK-III Compatible SSCNET III/H Compatible |
|||
Thermal Class | 130 (B) [UL/CSA is certified at 105 (A)] |
− | ||
Insulation Resistance |
100 MΩ or more when a 500 VDC megger is applied between the following places:
|
100 MΩ or more when a 500 VDC megger is applied between the following places:
|
||
Dielectric Strength |
Sufficient to withstand the following for 1 minute:
|
Sufficient to withstand the following for 1 minute:
|
||
Operating Environment (when operating) |
Ambient Temperature | 0~+40 °C (non-freezing)*2 | 0~+55 °C (non-freezing)*3 | |
Ambient Humidity | 85 % max. (Non-condensing) | |||
Atmosphere | Cable Type: No corrosive gases or dust. No exposure to water, oil or other liquids. Connector type: No corrosive gases or dust. No exposure to oil or other liquids. |
No corrosive gases or dust. No exposure to water, oil or other liquids. | ||
Degree of Protection | Cable Type: IP66 (Except for mounting surface and connector parts) Connector type: When the connection cable is connected IP66 (excluding the mounting surface, connection cable and the driver connector) |
IP10 | IP20 | |
Stop Position Accuracy |
AZM46, AZM48: ±4 arcmin (±0.067°) |
|||
Shaft Runout | 0.05 T.I.R. (mm)*4 | − | ||
Concentricity of Installation Pilot to the Shaft |
0.075 T.I.R. (mm)*4 | − | ||
Perpendicularity of Mounting Surface to the Shaft |
0.075 T.I.R. (mm)*4 | − | ||
Multi-Rotation Detection Range upon Power OFF |
± 900 revolutions (1800 revolutions) |
- *1
- (Only for types with electromagnetic brake)
- *2
- According to Oriental Motor’s measurement conditions
- *3
- When a heat sink of a capacity at least equivalent to an aluminum plate with a size of 200×200 mm and 2 mm thickness
- *4
- T.I.R. (Total Indicator Reading): The total dial gauge reading when the measurement section is rotated once around the reference axis center.
Note
-
Disconnect the motor and driver when measuring insulation resistance, or conducting a dielectric strength test.
Also, do not perform these tests on the ABZO Sensor part of the motor.

Standards
Regulations and Standards Materials
Documents about compliance with regulations and standards can be downloaded from the "Data Download" tab on the product details page.
(The types of files available for download vary by product.)
Explanations of the Global Laws, Regulations and Standards can be found here.
Information about our compliance with regulations and standards for each of our product series can be found here.
Hazardous Substances
The product does not contain any substances (10 substances) exceeding the regulation values of the RoHS Directive (2011/65/EU, 2015/863/EU).