Q.Is it possible to switch to a different number of operation data triggered by some signal during positioning operation with the AZ Series?
Operation data can be switched by the event jump function.
The event jump function is a function to split the operation according to the ON/OFF of the signal set in the "event trigger I/O" of the operation I/O event. When an "event trigger I/O" is detected during linked operation or loop operation, the operation is forcibly transitioned to the next data number.
Refer to the following video to learn the setting method.
[Setting Example when TLC Output is Used]
Back-and-Forth Operation Using Push-Motion Operation
[Setting Example when R0_R Output is Used]
Positioning Operation Using Sensor Detection
Product Category: αSTEP, electric actuators
Model and Series: AZ Series, electric actuators AZ Series equipped
Description: How to Use/Setting Method
FAQ No.: 309