Servo Motor: Servo Motor Inrush Current (Reference value)
Generally, a breaker (wiring circuit breaker) is used to prevent overcurrent from flowing due to a wiring short circuit or other factor.
When selecting a breaker, reference the "inrush current" values below, and the "input current" values listed on the product details page, or in the catalog specifications.
Servo Motors
Series | Power Supply Voltage [V] | Output Power [W] | Inrush Current [A] | |
---|---|---|---|---|
At Power ON | After 20 ms | |||
NX Series | Single-Phase 100-115 | 50, 100, 200 | 19 | 13 |
Single-Phase 200-230 | 37 | 12 | ||
Three-Phase 200-230 | 37 | 4 | ||
Three-Phase 200-230 | 400, 750 | 37 | 11 |
Related Information: Types of breakers to combine with AC motors and reference values