Cables: For 2-Phase Stepper Motor PKP Series/CVD Series Pulse Input Driver

Cable Configuration Figure for 2-Phase PKP Series
Number in Illustration
 
Cable Name
[1] Connection Cable
Flexible Connection Cable
[2] Extension Cable Driver Side
Flexible Extension Cable Driver Side
[3] Connection Cable Motor Side
[4] Connection Cable Without Terminal Treatment
  • *Use the flexible cable set for applications where cables are bent. Click here for note on use of flexible cables
Number in Illustration
 
Cable Name
[5] Encoder Connection Cable
[6] Connection Cable Set
[7] I/O Signal Cable
[8] DC Power Supply Cable
  • → For use in combination with the CVD Series RS-485 communication type driver,
    click here

Connection Cable

[1] Connection Cable, Flexible Connection Cables

  • Cable with connectors on both sides that directly connects the connector-coupled type motor and driver.
  • There are 2 types of connector shape. Select the cable suitable for each shape.
2-Phase PKP Series Connector Shape Model
Number in Illustration
 
Motor Applicable Drivers Cable Product Name
Frame Size Type Connector Configuration Pulse input
[1] 28 mm Standard Type
Standard Type With Encoder
High-Resolution Type
High-Resolution Type With Encoder
SH Geared Type
SH Geared Type With Encoder
CS Geared Type
Model B CVD215BR-K
CVD215B-K
CVD215-K
CCM□□□V2AAF
CCM□□□V2AAR
35 mm Standard Type
Standard Type With Encoder
CVD215BR-K
CVD215B-K
CVD215-K
CVD223BR-K
CVD223B-K
CVD223-K
CCM□□□V2ABF
CCM□□□V2ABR
42 mm Standard Type
High-Resolution Type
56.4 mm Standard Type
High-Resolution Type
CVD228BR-K
CVD228B-K
CVD228-K
CCM□□□V2ACF
CCM□□□V2ACR
42 mm Standard Type
Standard Type With Encoder
High-Resolution Type
High-Resolution Type With Encoder
SH Geared Type
SH Geared Type With Encoder
CS Geared Type
Model A CVD223FBR-K
CVD223FB-K
CVD223F-K

CCM□□□V2AEF
CCM□□□V2AER

42 mm/51 mm Flat Type
Flat Type With Harmonic Gearhead
50 mm Standard Type
Standard Type With Encoder
CVD228BR-K
CVD228B-K
CVD228-K
56.4 mm Standard Type
Standard Type With Encoder
CVD228BR-K
CVD228B-K
CVD228-K
CVD242BR-K
CVD242B-K
High-Resolution Type
High-Resolution Type With Encoder
CVD228BR-K
CVD228B-K
CVD228-K
60 mm SH Geared Type
SH Geared Type With Encoder
CS Geared Type

Note for Applicable Products

Connection cables suitable for the following motors are currently unavailable.

[1] Connection Cable, Flexible Connection Cable (Frame size: 28 mm)

[1] Connection Cable, Flexible Connection Cable (Frame size: 35 mm/42 mm)

[1] Connection Cable, Flexible Connection Cable (Frame size: 56.4 mm)

[1] Connection Cable, Flexible Connection Cable (Frame size: 42 mm, 50 mm, 51 mm, 56.4 mm, 60 mm)

[1] Connection Cable, Flexible Connection Cable (Frame size: 56.4 mm)

> > > > > > > > > > > >
Length (m) Connection Cable Flexible Connection Cable
Product NameProduct Name
Connection Cable for 2-Phase PKP Motor/CVD Driver
0.5 CCM005V2BEFCCM005V2BER
1 CCM010V2BEFCCM010V2BER
2 CCM020V2BEFCCM020V2BER
3 CCM030V2BEFCCM030V2BER
5 CCM050V2BEFCCM050V2BER

[2] Extension Cable Driver Side, Flexible Extension Cable Driver Side

  • These cables can be used to extend the connection cables.
  • When using an extension, keep the overall cable length at 10 m or less.
  • Up to 3 cables can be used for connection between motor and driver.

Note on Use of Flexible Cables

[2] Extension Cable Driver Side, Flexible Extension Cable Driver Side
(Applicable drivers: CVD242, CVD528, CVD538)

  • These cables can be used to extend the connection cables.
  • When using an extension, keep the overall cable length at 5 m or less.
  • Up to 3 cables can be used for connection between motor and driver.
Length (m) Connection Cable Flexible Connecion Cable
Product Name Product Name
Extension Cable for 2-Phase PKP Motor, 5-Phase PKP Motor/CVD Driver
0.5 CCM005V5BFFT CCM005V5BFRT
1 CCM010V5BFFT CCM010V5BFRT
2 CCM020V5BFFT CCM020V5BFRT
3 CCM030V5BFFT CCM030V5BFRT
4 CCM040V5BFFT CCM040V5BFRT

Note on Use of Flexible Cables

[3] Connection Cable Motor Side

Lead wire type connection cables with a connector crimped, convenient for connector-coupled motors, are available.

Product Name Applicable Product Length (m)
Frame Size Type
2-Phase PKP Connection Cable
LC2B06A 28 mm Standard Type
Standard Type With Encoder
High-Resolution Type
High-Resolution Type With Encoder
SH Geared Type
SH Geared Type With Encoder
CS Geared Type
0.6
LC2B10A 1
LC2B06B 35 mm
42 mm*1
Standard Type
Standard Type With Encoder
High-Resolution Type
0.6
LC2B10B 1
LC2B06C 56.4 mm*1 Standard Type
High-Resolution Type
0.6
LC2B10C 1
LC2B06E 42 mm*2
50 mm
51 mm
56.4 mm*2
60 mm
Standard Type
Standard Type With Encoder
High-Resolution Type
High-Resolution Type With Encoder
Flat Type
Flat Type With Harmonic Gearhead
SH Geared Type
SH Geared Type With Encoder
CS Geared Type
0.6
LC2B10E 1
LC2B10G 13 mm Standard Type 1
*1
Motor with connector shape model B
*2
Motor with connector shape model A

[4] Connection Cable Without Terminal Treatment

  • Connection cable for extending the distance between the motor and driver.
  • Can be used for bipolar wired motors with a motor rated current of 2.8 A max.
  • The overall length of the cable between the motor and the driver should be max. 10 m.
Length (m) Product Name
Connection cable without crimp terminal
5 CC05PK5
10 CC10PK5
  • *5-core cable (blue, red, orange, green, black). Do not connect the orange wire.

[5] Encoder Connection Cable

Encoder connection cable with encoder connector on the motor side.

Product Name Applicable Model Length (m)
Connection Cable for Connecting Encoder
LCE05A-006 Voltage Output Type 0.6
Connection Cable for Connecting Encoder
LCE08A-006 Line Driver Output Type 0.6

Flexible, shielded connection cable for encoder.

Product Name Applicable Product Length (m)
Connection Cable for Connecting Encoder
CC010E1R Line Driver Output Type 1
CC020E1R 2
CC030E1R 3

Other Cables

This cable can be used to connect the driver and controller.

[6] Connection Cable Set

The set includes connection cables for connecting motor, power supply, and I/O signal to driver.
The connector is attached to the driver side.

Product Name Applicable Product Connector Name Connector Product Name Length conductor
AWG
Connection Cable Set
LCS01CVK2 2-Phase Stepper Motor PKP Series/CVD Series Pulse Input Driver
(excluding CVD242 and CVD245)
For Motor 51103-0500 0.6 m 22
(0.3 mm²)
For Power Supply 51103-0200
For I/O Signals 51103-1200
LCS02CVK2 2-Phase Stepper Motor PKP Series/CVD Series Pulse Input Driver
(CVD242, CVD245)
For Motor 51067-0500 20
(0.5 mm²)
For Power Supply 51067-0200
For I/O Signals 51103-1200 22
(0.3 mm²)

[7] I/O Signal Cable

Product Name Length
(m)
I/O Signal Cable
CC12D005-2 0.5
CC12D010-2 1
CC12D015-2 1.5
CC12D020-2 2

[8] DC Power Supply Cable

Product Name Applicable Product Length
(m)
DC Power Supply Cable
CC02D005-2

For 2-Phase Stepper Motor
Bipolar Driver
(product name example: CVD2~)

  • *excluding CVD245
0.5
CC02D010-2 1
CC02D015-2 1.5
CC02D020-2 2
DC Power Supply Cable
CC02D005-4 For 2-Phase Stepper Motors
Bipolar Driver
CVD242, CVD245
0.5
CC02D010-4 1
CC02D020-4 2

Cable Note When Wiring Flexible Cable

Do not bend the cable at the connector. Stress applied to the connectors and terminals causes poor contact and disconnection.

How to Fix the Cable

Fix the connector part in 2 places to prevent it from moving.

Fix the connector part in 2 places to prevent it from moving.

Wiring Length and Bending Radius of the Cable

Wiring should be installed at an appropriate length, so that cables are not pulled during movement.
In addition, the bending radius (R) should be 6 times the cable diameter min.

Wiring should be installed at an appropriate length, so that cables are not pulled during movement.

Interference of the Cable

Wire the cables in the cable holder without bringing them into contact with each other. This will add stress to the cable, and cause it to break prematurely. Please check note on cable holders carefully before use.

Cable Kinks

◇Please wire without kinks in the cable. Kinking in a twisted state can cause premature disconnection. After wiring, confirm that there are no kinks in the cable, using the print on the cable surface as a reference.