Wiring Support Component Connection Support Module
Components and circuits useful for connecting motor control devices have been made into small boards in this module. Use it to meet your needs for improved reliability, reduced production time, and space saving.
External Resistor Module
External resistors required for connection to controllers with 24 VDC output power are available.
There are 5 resistors on its board. The terminal block allows easy and reliable connection.
>For DIN rail installation.
>Can be used for driver input signals. Any type of driver can be used.
Product Name | Applicable Products | ||
---|---|---|---|
Series Name | Driver Product Name | ||
![]() |
VCS01 | AZ | AZD |
RKII | RKSD | ||
CVK | CVD | ||
CRK | CRD | ||
CMK | CMD |

CR Circuit Module
This is a support module for reliable and easy connection of CR circuits for surge suppression.
Contact protection for relays and other devices can be easily achieved.
For DIN rail installation.
Product Name | |
---|---|
![]() |
VCS02 |

Logic Inversion Module
A board with a signal logic inversion circuit for 2 signals is available.
Can be used for a variety of applications. For DIN rail installation.
Note) VCE (sat) (ON voltage) remains 0.3 to 1 V at the output.
Note that this product cannot be used with products (AZ Series, RKII Series, etc.) whose VCE (sat) of the output circuit is 0.5 V min.
Product Name | |
---|---|
![]() |
VCS03-2 |
Specifications
- Power Supply Voltage
- 5 to 24 VDC±10 %
- Input Signals
- Connect the open-collector output.
Internal Pull-Up Resistor 5.6 kΩ (L level 0 to 0.5 V)
- Output Signals
- Open-collector output
30 VDC or less, 120 mA or less
VCE (sat) (ON voltage) remains 0.3 to 1 V.
Example of Wiring

Logic Inversion Module Photocoupler Input Type
A board with a signal logic inversion circuit for 2 signals is available.
24 V signal can be input directly.
The presence or absence of power supply input can be checked with LEDs.
For DIN rail installation.
Product Name | |
---|---|
![]() |
VCS03-3 |
Specifications
- Power Supply Voltage
- 5 to 24 VDC±10 %
- Input Signals
- Photocoupler input
Input signal voltage 18.1 to 26.4 V (Between terminals)
Maximum response frequency 100 kHz (50 % duty)
- Output Signals
- Open-collector output
30 VDC or less, 120 mA or less
VCE (sat) (ON voltage) 0.5 V or less
Example of Wiring

Pulse Signal Splitter
This module distributes pulse signals into 2 parts so that 1 single pulse generator (controller) can carry out synchronous operation of 2 drivers.
Product Name | |
---|---|
![]() |
VCS04 |
Specifications
- Input Mode
- Photocoupler input
- Output Mode
- Open-collector output
Features
- 1 pulse signal can be divided into 2 separate outputs.
- DIN rail installation makes it easy to install near drivers and pulse generators.


Line Driver Module (Pulse signal converter for noise immunity)
This module uses a line driver to re-output pulse signals that were output by an open-collector.
For DIN rail installation.
Product Name | |
---|---|
![]() |
VCS06 |
Specifications
- Input Mode
- Photocoupler input
- Output Mode
- Line driver output
Features
- This product can handle pulses pulled up at 24 VDC and pulses pulled up at 5 V.

Line Receiver Module
This is a signal output converter that receives the output signal that was output by a line driver with a line receiver and re-outputs it with an open collector.
For DIN rail installation.
Product Name | |
---|---|
![]() |
VCS07 |
Specifications
- Power Supply Input
- 12 to 24 VDC±10 % 30 mA
- Input Signals
- IN1 to 4: Line receiver 26C32 equivalent
- Output Signals
- OUT1 to 4: Open collector 30 VDC, 20 mA max.
- Maximum Response Frequency
- 500kHz

USB to RS-485 Converter
This module converts a PC's USB port to the RS-485 serial interface.
For DIN rail installation.
Product Name | Applicable Products | |||
---|---|---|---|---|
Series Name | Driver Product Name | Type | ||
![]() |
VCS08 | AZ Series | AZD | Built-in controller type RS-485 communication type Pulse input type with RS-485 communication |
AR Series | ARD | Built-in controller type | ||
RKII Series | RKSD | |||
CRK Series | CRD | |||
BLE Series | BLED | RS-485 communication type | ||
BLV Series | BLVD | - |
Specifications
USB | Interface | : USB 2.0 Full speed 12 Mbps |
---|---|---|
Connector | : MiniB (Female) | |
RS-485 | Electrical Characteristics | : EIA-485 compliant |
Communication Method | : Half duplex (Built-in 120 Ω termination resistor) | |
Transmission Rate | : 9,600 to 230,400 bps | |
Power Supply | Power Supply Method | : USB bus powered |
Power Supply Voltage | : 5 VDC | |
Current Consumption | : 70 mA (200 mA or less) |
Operating Environment
Windows: | Microsoft Windows 10 |
---|---|
Microsoft Windows 11 | |
Linux: | Ubuntu 22.04.2 |
Raspberry Pi OS/2023-5-03 | |
(Debian GNU/Linux 11 bullseye) |
Features
- Drivers compatible with RS-485 communication can be controlled from a PC via Modbus communication.
- The PC (USB connector GND) and the driver (RS-485 connector GND) are isolated.
- USB bus powered, no external power supply required.
Device Driver
For Windows
Can be used as a Windows COM port by installing the device driver.
To download device drivers, click here
*After extracting the compressed file, right click on silabser.inf and select install.
For Linux
Use the drivers that come standard equipped with Linux distribution.
Follow the steps below to grant read and write permissions to the serial port to which the VCS08 is connected.
- Connect the VCS08 to the computer.
The VCS08 will automatically be recognized and a device file as "ttyUSB0" will be generated under "/dev." - The "0" in the device file name will vary depending on the environment, enter the following command into terminal to check.
Enter the command, the device file name will display as "/dev/ttyUSB0".
If multiple device file names are displayed, unplug and plug the VCS08 to confirm. - Enter the following command into the terminal, grant read and write permission to the serial port.
Example: For device file name is "ttyUSB0"
Connection Example