Q.I am using an AZ Series EtherNet/IP compatible driver. Is it necessary to wire direct I/O (CN7)?
Direct I/O allows you to operate the motor via EtherNet/IP without wiring.
However, wiring will be required in the following cases.
- To use a sensor with a positive limit switch and a negative limit switch for safety.
- To perform return-to-home using the home sensor
- To input I/O using switches, etc.
- To run a motor using pulse input
- To physically check the output
Direct I/O is connected to the I/O signal connector (CN7)*.
- *The input/output signal connector for AZD-KREP is CN5.

Direct I/O assignments can be changed using the support software MEXE02 or EtherNet/IP communication.
- *The direct I/O signal assignment change is reflected during configuration or when the power supply is rebooted.
Related Information: AZ Series EtherNet/IP TM compatible driver FAQ
Product Category: αSTEP, electric actuators
Model and Series: AZ Series, electric actuators equipped with AZ Series
Description: Wiring method, usage and setting method
FAQ No.: 558
Email to Technical Support
After opening the email, we will check the contents and contact you. Please note that depending on the nature of your enquiry, we may contact you by phone.