Servo Motor: Servo Motor Inrush Current (Reference value)

Generally, a breaker (wiring circuit breaker) is used to prevent overcurrent from flowing due to a wiring short circuit or other factor.
When selecting a breaker, reference the "inrush current" values below, and the "input current" values listed on the product details page, or in the catalog specifications.

Servo Motors

Series Power Supply Voltage [V] Output Power [W] Inrush Current [A]
At Power ON After 20 ms
NX Series Single-Phase 100-115 50, 100, 200 19 13
Single-Phase 200-230 37 12
Three-Phase 200-230 37 4
Three-Phase 200-230 400, 750 37 11

Related Information: Types of breakers to combine with AC motors and reference values