CVD Series SC Type Speed Setting Method

Speed Setting

The CVD Series SC Type can be set to 2 different operating speeds: high speed (Speed 1) and low speed (Speed 2).

Speed 1:
Operating speed on the high speed side when M0 input is turned OFF
Speed 2:
Operating speed on the low speed side when M0 input is turned ON
Operating Speed

Setting Method (Overview)

Use "Function Setting Switch" and "Speed Setting Switch" to perform speed setting.

Switch Setting

Flow of Setting

Select maximum speed of speed 1. (200 r/min or 600 r/min)
Select setting method of Speed 2*
Set the operating speed for Speed 1 and Speed 2*
Set acceleration time and deceleration time. (Select from 0.00 s to 3.00 s between 0 and 600 r/min)
Select operating current rate. (100 % or 70 %)
  • *There are 2 setting patterns for Speed 1 and Speed 2, and the setting of the SPD2 EN switch (function setting switch No. 2) changes as follows.
Setting Pattern SPD2 EN
Switch
Speed Setting Method Switch Used
Pattern 1 OFF Speed 1 Select 1 of 256 different speeds ×16/SPD1 and ×1/SPD2 are used together
Speed 2 Fix to 10 % speed of Speed 1 None
Pattern 2 ON Speed 1 Select 1 of 16 different speeds ×16/SPD1
Speed 2 Select 1 of 16 different speeds, ranging from 0.5 to 50 % of Speed 1 ×1/SPD2

For details, refer to the Operating Manual (CVD Series SC type).