Types of Driver Cables

Connection Cable Set

Connection Cable Set

This is a set of lead wires with connectors for wiring DC drivers. It is 1 set of lead wires with connectors for the motor, power supply, and I/O signals.

Connection Cable: Power Supply Cable, Signal Cable

Connection Cable: Power Supply Cable, Signal Cable

This is a shielded cable with a connector for DC driver wiring. To facilitate shield grounding, grounding wires with round terminals are provided from both ends of the cable.

General-Purpose Cable: For I/O Signals

General-Purpose Cable: For I/O Signals

This is a multi-core shielded cable useful for I/O signal wiring of various speed controllers and drivers. To facilitate shield grounding, grounding wires with round terminals are provided from both ends of the cable.

General-Purpose Cable: Straight Type, Right-Angle Type

General-Purpose Cable: Straight Type, Right-Angle Type

This is a shielded cable with connector that fits the half-pitch connector mounted on the driver. At the other end of the cable, the laminated lead wires are arranged in the 1.27 mm pitch, which are useful for crimp connectors. To facilitate shield grounding, grounding wires with round terminals are provided from both ends of the cable.

Connector and Terminal Block Conversion Unit

Connector and Terminal Block Conversion Unit

This is a unit of shielded cables with connectors and terminal blocks that fit the half-pitch connector mounted on the driver. I/O signals of the driver can be easily connected with the terminal block. To facilitate shield grounding, grounding wires with round terminals are provided from both ends of the cable.

FLEX Communication Cable: General-Purpose Cables, Dedicated Cable

FLEX Communication Cable: General-Purpose Cables, Dedicated Cable

This cable is convenient for connecting FLEX compatible products to various equipment that is Modbus-controlled by RS-485.
A general-purpose type with a discrete wire at one end of the cable, and a dedicated type that can be directly connected to programmable display units manufactured by Schneider Electric Holdings, Inc. and Hakko Electronics Co., Ltd.

Cable Note When Wiring Flexible Cable

Do not bend the cable at the connector. Stress applied to the connectors and terminals causes poor contact and disconnection.

How to Fix the Cable

Fix the connector part in 2 places to prevent it from moving.

Fix the connector part in 2 places to prevent it from moving.

Wiring Length and Bending Radius of the Cable

Wiring should be installed at an appropriate length, so that cables are not pulled during movement.
In addition, the bending radius (R) should be 6 times the cable diameter min.

Wiring should be installed at an appropriate length, so that cables are not pulled during movement.

Interference of the Cable

Wire the cables in the cable holder without bringing them into contact with each other. This will add stress to the cable, and cause it to break prematurely. Please check note on cable holders carefully before use.

Cable Kinks

◇Please wire without kinks in the cable. Kinking in a twisted state can cause premature disconnection. After wiring, confirm that there are no kinks in the cable, using the print on the cable surface as a reference.